Advanced explosion-proof smart temperature transmitter with barograph/programmable LCD display and local configuration keys. Universal input supports RTD, TC, mV, and Ω sensors. Indication in P.V., mA, and %.
Programmable LCD with backlight for trend visualization
Local zero, span, and damping adjustment without HART communicator
Display in P.V., mA, and % — all standard & customized engineering units
Casing design enables display rotation and choice of cable direction
| Sensor Type | Model | Range | Min. Range | Accuracy |
|---|---|---|---|---|
| Thermocouple | T | -200~400°C | 25°C | ±0.4°C |
| Thermocouple | E | -200~1000°C | 25°C | ±0.4°C |
| Thermocouple | J | -210~1200°C | 25°C | ±0.4°C |
| Thermocouple | K | -200~1372°C | 25°C | ±0.4°C |
| Thermocouple | N | -200~1300°C | 25°C | ±0.4°C |
| Thermocouple | R | 0~1768°C | 100°C | ±0.8°C |
| Thermocouple | S | 0~1768°C | 100°C | ±0.8°C |
| Thermocouple | B | 150~1820°C | 100°C | ±1.0°C |
| RTD | PT50 | -200~850°C | 10°C | ±0.15°C |
| RTD | PT100 | -200~850°C | 10°C | ±0.15°C |
| RTD | PT500 | -200~850°C | 10°C | ±0.1°C |
| RTD | PT1000 | -200~850°C | 10°C | ±0.1°C |
| mV Input | — | -120~120mV | 10mV | ±10µV |
| mV Input | — | -1000~1000mV | 50mV | ±100µV |
| Ω Input | — | 0~500Ω | 100Ω | ±0.2Ω |
| Ω Input | — | 0~4500Ω | 100Ω | ±1.0Ω |
HART output • Universal input (no sensor) • LCD with keys • Lightning protector • SS316 enclosure • Material test • SS304 bracket
⚠ Notice:
When sensor order code is "0" (without integrated sensor), the user must prepare suitable sealing for assembling the remote sensor in its conduit to achieve the desired IP rating and explosion-proof protection.
| Feature | STEX15 | STEX25 |
|---|---|---|
| Display | Optional / Without LCD | LCD Standard (Barograph) |
| Local Config Keys | — | 3 Keys (Zero/Span/Damping) |
| Indication | — | P.V., mA, % |
| Electrical Conduits | One × M20×1.5 | Two × M20×1.5 |
| Weight | ≈ 250g | ≈ 0.6 kg |
| Dimensions | ≈ 7×7×10 cm | ≈ 10×17×10 cm |
| Lightning Protector (/A1) | — | ✓ Available |
| Sensor Accuracy (RTD) | ±0.1°C | ±0.1°C |
| Isolation | 1000VDC | 1000VDC |
Contact our technical team for sensor selection, LCD configuration, and competitive pricing.
Request Quote →